Katherm NK

Trench technology for heating

The Katherm NK heats with natural convection without fan assistance.

 

  • Heating
An einer Fensterfront im Boden installierte Katherm NK Unterflurkonvektoren.
An einer Fensterfront im Boden installierte Katherm NK Unterflurkonvektoren.

Warm rooms, condensation-free windows

With the Katherm NK, you can ensure warm rooms and condensation-free glass façades at the same time. The trench technology uses natural convection to effectively screen window surfaces from cold air and prevent condensation from forming, while pleasantly heating the entire room. Ideal for buildings with large glass surfaces and no visible radiators.

Wide range of variants

The wide selection of sizes offers a suitable solution for every project. Depending on the installation situation, the channel is complemented by a color-coordinated grille and a suitable frame edge, creating maximum flexibility in planning. Removable end pieces make it possible to create continuous channel runs that blend harmoniously into the façade.

7128 variants

Various heights are available, as well as a wide selection of performance-graded widths and lengths.

Custom-made to measure

Custom-made solutions are possible for any building architecture with individual geometries. This applies to both the channel and the grille. Possible examples include:

  • Mitred corners
  • Curved versions
  • Angles and slopes
  • Column cut-outs
  • Various grille variants
  • Frame edges

Short installation time

The valve connection enables quick and easy installation of the Katherm NK on site. In addition, height adjustment screws are supplied as standard together with step-safe height adjustment feet to further reduce installation time and therefore costs.

Protection during installation and construction

Our Katherm trench technology products are carefully packed in cardboard packaging for transport. The grille edge trim profiles are protected against damage by green plastic profiles. A sustainable paper cover prevents dust and dirt from entering.

As the units are often installed in the building at an early construction stage, the grille can be replaced at the factory with a wooden installation cover for their protection for an additional charge. The grilles are then supplied separately packed.

Technical features

Cold air screening

  • Cold air screening and residual heat coverage are provided specifically by utilizing the special property of natural convection.
  • The convector transfers the heat of the water to the room air, which then rises on the window side, effectively screens the cold glass surface and thus prevents the windows from misting up.

Introduction of primary air

  • Primary air or fresh air is introduced into the rooms via special supply air ducts.
  • The Katherm supply air duct ZL is available for numerous Katherm trench technology units.
  • This is a duct, that can be attached to the respective Katherm units depending on the version.

Life cycle assessment data (EPD)

  • We assess the environmental impact of our products across their entire life cycle („cradle to cradle“) and publish the results transparently in our Environmental Product Declarations (EPD).
  • These EPDs can be easily integrated into leading building certification systems such as DGNB, BREEAM or LEED and are available in the download section.

Static heating requirements

  • Rooms with relatively static heating requirements, such as corridors, hotel lobbies, conservatories or living rooms, are particularly suitable for the use of Katherm NK.
  • The performance-optimized Perimeter Heating in low-temperature and heat pump operation ensures energy-efficient operation and keeps operating costs at a low level.

No sound emissions

  • The Katherm NK operates without a fan, purely with natural convection.
  • This makes it particularly suitable for installation in noise-sensitive application areas.

Control options

Electromechanical control

This variant is ideal for simple applications. All integrated actuators are factory-wired to a terminal and can be connected to our electromechanical accessories such as thermostats or external controllers.

Selection options

Adapt the product to your requirements these options are available for selection.

Roll-up grille

Linear grille

Grille version

Various versions in material and color, usable on both sides

Product finder

With our free calculation program, you can find the product with the right performance data for your project in just a few steps. You can then download the official technical data sheet with your individual project values as a PDF.

Calculate product

Project solutions

An einer Fensterfront im Boden installierte Katherm NK Unterflurkonvektoren.

Mauerstetten

Mayr Antriebstechnik

Mauerstetten

Mayr Antriebstechnik

  • New build of a communications center
  • Katherm NK (> 80 linear meters)
#Trench Technology
An einer Fensterfront installierte Katherm NK Unterflurkonvektoren.

Plochingen

Volksbank branch

Plochingen

Volksbank branch

  • New construction of office and event spaces
  • 238 m² GK50WT
  • 409 m² MDCU
  • RRA
  • 9 x Katherm NK (in various versions with 6 mitred corners)
#Diffusers
#Trench technology
#Heating and cooling ceiling systems
In dem Gebäude eingesetzter Unterflurkonvektor Katherm HK mit Gehrungsecke.

Łódź

Primulator

Łódź

Primulator

  • Design-oriented new construction of the company headquarters
  • Katherm NK
  • Katherm HK
  • Venkon
  • KaCool D
#trench technology
#Fan Coils
Nahaufnahme von Katherm NK Unterflurkonvektoren.

Munich

Revo Hotel

Munich

Revo Hotel

  • More energy-efficient building area
  • 612 x Venkon
  • 91 x Kacool D AF
  • Katherm NK
#trench technology
#Fan Coils
Ein eingesetzter Unterflurkonvektor Katherm NK.

Cologne

25hours Hotel The Circle

Cologne

25hours Hotel The Circle

  • Revitalization of a retro-futuristic circular building
  • 212 x Venkon
  • 6 x Kacool D
  • Katherm NK
#trench technology
#Fan Coils
Der Blick geht durch eine moderne Fensterfassade des Genfer Flughafens, mit davor installierten Unterflurkonvektoren Katherm NK, auf eine weißes Emirates Boeing 777-300ER, die bereit zum Boarding ist.

Geneva

Geneva Airport

Geneva

Geneva Airport

  • New construction of the "Aile Est" terminal
  • 2.2 km Katherm NK
  • Optiline design grilles 
#Trench technology
#Design grilles
Ein geräumiger Flur mit Gewölbedecke, runden Lichtelementen, Kunstwerken an den Wänden, Holzbänken und einem großen, orangefarbenen Teppich schafft eine einladende Atmosphäre. Im Boden vor der Eingangstür sind Katherm NK Unterflurkonvektoren installiert.

Salzburg

Hellbrunn Palace

Salzburg

Hellbrunn Palace

  • World-famous palace receives new visitor center
  • 15 x Katherm NK with fresh-air supply function
  • Optiline in aluminum, bronze anodized
#Trench technology
#Design grilles
Ein im Fitnessraum eingesetzter Unterflurkonvektor Katherm QK.

Vienna

Quartier Belvedere Central

Vienna

Quartier Belvedere Central

  • Lively new district near the main railway station
  • Katherm NK
  • Katherm QK
#Trench Technology

Downloads

Product documents

All relevant documents for this product provided in a compact format.

Go to the download center

Frequently asked questions

We're happy to help.

Find your contact person in our extensive sales network.

Calculate now