The optimized Katherm HK P in size 310/160 is based on a modular system design and is especially suitable for projects requiring both heating and cooling capacity as well as controlled ventilation. It features primary air connections with air nozzles or for air intake via the raised floor. The tangential fans operate quietly and energy-efficiently and ensure optimum air distribution.


The innovative modular concept of the Katherm HK P is divided into three core elements: connection module, power module and extension module. The parametric design of the power module, adjustable in 100-mm intervals, offers around 12,000 configuration options. This guarantees precise adaptation to the respective facade conditions with maximum output efficiency.

As a new variant in parametric design, the Katherm HK P is initially available in a fixed width and height. Depending on on-site requirements, various product-specific lengths are available in flexible increments to cover all performance requirements in both two-pipe and four-pipe systems.
Additional heights and widths (H/W) with supply air function via supply air modules or supply air ducts can be found here:
The connection module contains the electrical connection and control box, the continuously variable EC fan motor, the water-side heat exchanger connection and the waste-water-side condensate connection with an optionally selectable condensate pump . Valve kits for 2- or 4-pipe systems are available on request. All electrical components are pre-installed in the central connection box. This module combines all connections to the electrical, heating and waste-water trades on one connection side, enabling efficient, time-saving installation.
With the power module in the Katherm HK P, we achieve higher heat exchanger output. A single powerful drive motor activates a series of tangential fans by means of an innovative coupling system. This cascading minimises performance losses and ensures uniform flow across the entire convector length. The use of fewer but more powerful motors reduces resource use, energy consumption and susceptibility to faults in projects. This makes the system an efficient and sustainable alternative to conventional multi-fan solutions.

The newly designed Katherm HK P makes optimum use of the available floor space to achieve maximum output with low noise. In 4-pipe systems, the extension module (right channel section) serves as the additional valve connection for heating mode. In 2-pipe variants, the section is reduced to a minimum. Every millimeter is used efficiently and the channel is flexibly adapted to local conditions. This sophisticated design guarantees maximum space utilization of the trench unit.
Our custom-made channel and grille solutions integrate seamlessly into any building structure. From miters and curves to angles, slopes and column surrounds – everything is possible. Various grille versions and frame designs are available to choose from.
Contact us for customized advice on the ideal solution for your project!

Our heat exchanger is equipped with an internal thread connection and an anti-torsion device, which also provides splash protection during venting. The valve range extends from adjustable on/off valve kits to pressure-independent valve kits for various flow rates, complete with corrugated pipes. All options can be preassembled at the factory, so that on site only one press connection on the copper end piece of the corrugated pipe is required .
Our system offers sophisticated condensate management with an integrated collection tray for reliable condensate drainage in cooling mode. Drainage takes place by natural gradient or by means of an optional pump, which can be installed on site or at the factory. The new pump design combines float and motor in one compact housing. A newly designed connection elbow for the tray is included, saving installation time and simplifying maintenance. The extremely quiet pump continuously adjusts its output. Preinstalled plug connections for power supply and fault signal also make maintenance easier.
Our system uses sound-decoupled tangential fans, which are mounted using a special coupling and ball stud mechanism to minimize operating noise. The fans can be removed without tools for maintenance – straightforward and time-saving. This ensures a pleasantly quiet room atmosphere together with effortless Maintenance.

Protecting your systems is our highest priority during delivery and installation. That is why we protect every channel against construction waste with environmentally friendly paper. For the initial phase of interior finishing, an optional wooden cover ex works is available.
The grilles are delivered separately and securely packed by us to guarantee that they remain undamaged.
With the integrated KaControl MC control, Katherm HK P offers bidirectional communication for up to 10 units within one group/room via CAN bus. With KaControl MC, the unit can be easily integrated into common building management systems such as Modbus RTU, Modbus TCP, BACnet/IP and KNX-TP.
This variant is ideal for simple applications. All integrated actuators are factory-wired to a terminal and can be connected to our electromechanical accessories such as thermostats or external controllers.
Adapt the product to your requirements – these options are available for selection.
Heating or cooling (central switch-over possible)
Simultaneous heating and cooling in different usage zones
Wide range of versions in material and color. Can be used on both sides. Shortenings and extensions are also possible.

With our free calculation program, you can find the product with the right performance data for your project in just a few steps. You can then download the official technical data sheet with your individual project values as a PDF.
Our improved model in size 310/160 with primary air connection complies with the VDI 6022 hygiene standard. Condensate pump, connection and tray are installed in the trench unit. The tangential fan can be easily removed via plug connections, allowing the condensate tray to be pulled out for thorough cleaning. This sophisticated design guarantees hygienic and user-friendly operation.
We assess the environmental impact of our products across their entire life cycle („cradle to cradle“) and publish the results transparently in our Environmental Product Declarations (EPD). These EPDs can be easily integrated into leading building certification systems such as DGNB, BREEAM or LEED and are available in the download section.

Separate ventilation and temperature control with a hybrid ventilation concept: The combination of central ventilation via an AHU unit and decentralized air conditioning with pumped hot water and chilled water enables efficient heating and cooling.

Rheine
Apetito - company restaurant

Rheine
Apetito - company restaurant
Rheine

Immenstadt
Albrecht Electrical Engineering

Immenstadt
Albrecht Electrical Engineering
Immenstadt

Eislingen
Prinzing Electrical Engineering

Eislingen
Prinzing Electrical Engineering
Eislingen

Lübeck-Travemünde
SlowDown

Lübeck-Travemünde
SlowDown
Lübeck-Travemünde

Berlin
Hotel RIU Plaza

Berlin
Hotel RIU Plaza
Berlin

Riva del Garda TN, Italy
Hotel Lido Palace

Riva del Garda TN, Italy
Hotel Lido Palace
Riva del Garda TN, Italy