• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Fan Coils
        • Venkon XL
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Downloads

        Radial fan

        • Directly driven radial fan with forward curved impellers in stepless EC design

        High-output heat exchanger

        • made of proven copper/aluminum combination
        • Optimized for maximum power output

        Condensate tray

        • Can be easily and conveniently removed for maintenance/cleaning
        • Optionally available: valve condensate tray that can be mounted on the side of the unit

        Condensate drain

        • Available as accessories
        • For controlled removal of condensate during humid cooling
        • incl. mounting bracket for float switch

        Filter

        • Easy to remove
        • Optional filter quality class ISO ePM10>50% (M5/MERV8) or ISO ePM1>50% (F7/MERV13)

        Connection unit for circular pipe

        • Optionally mounted ex works
        • High flexibility due to variable number of spigots

        Electrical junction box

        • electromechanical or KaControl MC1
        • Networking option with higher-level systems (e.g. Modbus, BACnet, KNX)

        Model size

        The units are available in several model sizes to allow the performance to be tailored to requirements. The model size is selected depending on the required thermal output, the air volume flow and the sound requirements of the room. Larger model sizes offer higher performance, but are associated with larger housing dimensions, which must be taken into account when planning the installation situation.

        Model sizeControl optionLength (A)Depth (B)Height (C)
        1electromechanical with fault signal contact616 mm262 mm650 mm
        1electromechanical without fault signal contact616 mm262 mm650 mm
        1KaControl MC1736 mm262 mm650 mm
        2electromechanical with fault signal contact916 mm262 mm650 mm
        2electromechanical without fault signal contact916 mm262 mm650 mm
        2KaControl MC11036 mm262 mm650 mm
        3electromechanical with fault signal contact1366 mm262 mm650 mm
        3electromechanical without fault signal contact1366 mm262 mm650 mm
        3KaControl MC11486 mm262 mm650 mm
        4electromechanical with fault signal contact1716 mm262 mm650 mm
        4electromechanical without fault signal contact1716 mm262 mm650 mm
        4KaControl MC11836 mm262 mm650 mm

        installation site

        The installation location determines the basic structure of the unit.

        The ceiling version has been specially developed for horizontal installation on the ceiling, with the air outlet facing forwards. The wall-mounted model, on the other hand, is designed for vertical installation on walls, with the air outlet facing upwards.

        The two variants are not compatible with each other due to the design differences - particularly in the condensate tray and condensate drainage. Each version is specifically designed for fixing, condensate drainage and maintenance accessibility.

        The selection of the right variant should therefore always be based on the structural conditions and maintenance requirements.

        Installation site
        Ceiling-mounted
        Wall-mounted

        System

        2-pipe system

        With this design, the entire heat exchanger surface is available for temperature control, depending on the medium currently present in the pipe system (cold or hot water). Switch-over between heating and cooling takes place centrally via the building management system. This variant is particularly suitable for applications with seasonal switch-over and reduced installation effort.

        4-pipe system

        This version is suitable for sophisticated air conditioning concepts in which each room zone or unit can be switched over individually between heating and cooling. By routing the heating and cooling medium separately, the system offers maximum flexibility and comfort - ideal for buildings with changing usage requirements.

        Type of system
        2-pipe
        4-pipe

        Water connections

        Depending on the structural conditions and installation requirements, two connection variants can be selected:

        Left or right connection.

        These variants enable optimum adaptation to the pipe routing on site and reduce both installation work and costs.

        For wall-mounted units, the connection side is defined from the viewing angle of the mounted unit.

        For ceiling-mounted units, please refer to the technical drawing or installation instructions for the definition.

        Water connections
        left
        right

        Filter class

        Different filter types are available depending on the application area and the air quality requirements.

        The standard version with an ISO Coarse filter primarily serves to protect the device by retaining coarse particles such as dust and fibers.

        For applications with increased demands on indoor air quality, more powerful filters in accordance with ISO ePM, MERV or HEPA can be integrated as an option. These improve the indoor air by removing fine particles and aerosols from the intake air.

        The suitable filter should be selected taking into account the project-specific requirements and the planned maintenance intervals.

        Filter class
        Filter ePM1>50% (F7)
        Filter ePM10>50% (M5)

        Control option

        We offer various solutions for the control and regulation of our units, which can be used depending on the application and requirements:

        Electromechanical control

        This variant is ideal for simple applications. All integrated actuators are factory-wired to terminals and can be connected to our electromechanical accessories such as thermostats or external controllers.

        KaControl MC1

        Our comprehensive comfort control offers extended control options for individual rooms or appliance groups. It can be operated either via a touch display or a web interface. Thanks to on-site 0-10 V control or common communication protocols such as Modbus RTU & TCP, BACnet and KNX, this solution is ideal for all BMS applications.

        Control option
        electromechanical with fault signal contact
        electromechanical without fault signal contact
        KaControl MC1

        Installation distances and heights

        • The air outlet area needs to be completely barrier-free.
        • A distance of 100 mm from the air intake area must be maintained.
        • With cladding, at least 50 mm must be freely accessible in the direction of the air outlet area.
        • A distance of 100 mm must be maintained from the underside of the device.
        • A distance of 215 mm must be maintained from the sides.
        • At the rear, a minimum clearance of 100 mm is required for ceiling mounting.

        Connection options

        • Wall-mounted - water connection side on the left (Fig. 1)
        • Wall-mounted - water connection side right (Fig. 2)
        • Ceiling mounting - water connection side left (Fig. 3)
        • Ceiling mounting - water connection side right (Fig. 4)

        Choice of the installation site

        • No obstruction in air distribution and air intake
        • Full-surface revision option
        • Minimum distance to occupied zone with casing 1.5 m
        • Secure fastening options must be available

        Avoid the following:

        • Impairment of free air circulation due to e.g. lamps, furniture or shelves
        • Obstruction of air intake and air distribution
        • Electronic units below the unit
        • Inaccessibility for maintenance work

        Air connection

        • Variable number of spigots depending on structural conditions and air requirements
        • Round tube diameter selectable: 100 - 200 mm
        • Number of spigots as a function of volumetric flow and spigot speed
        • The connected duct network must not cause pressure losses >180 Pa.

        Hygiene compliance

        • Complies with the relevant hygiene guideline VDI 6022
        • Goal: Ensuring hygienic supply air that is harmless to health
        • Applies to common rooms such as workplaces, meeting rooms, break rooms, living rooms, sports facilities and sales rooms.
        • With factory-fitted ISO Coarse filter in the intake area.
        • Accessibility of all ventilated and water-bearing components for cleaning.

        Life Cycle Assessment Data (LCA)

        • Considers the environmental impact of the product over its entire life cycle.
        • Published as an Environmental Product Declaration (EPD) in accordance with standard EN 15804.
        • Available for download at International EPD System.
        • Item number-specific life cycle assessment data in the technical data sheets.
        • Product is registered in the DGNB Navigator (building product platform).

        Serves as proof for certification systems, e.g:

        • DGNB (German Sustainable Building Council);
        • BREEAM (Building Research Establishment Environmental Assessment Method);
        • LEED (Leadership in Energy and Environmental Design).

        Results per page

          Results per page

          Page 1 of 0

          Results per page

            Results per page

            Page 1 of 0

            Venkon XL

            Fan coils, recirculating air. Heating, cooling, for raised external pressure.

            • Heating
            • Cooling
            • Ventilation
            Product image