• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Fan Coils
        • KaCool D AF
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Videos
        • Downloads

        Maximum comfort with AtmosFeel

        • Comfortable heating and cooling
        • Extensive design variants for every application
        • with design ABS panel as standard, alternatively available with metal panel (optional)
        • fulfills the requirements of VDI 6022

        Heat exchanger

        • High-efficiency heat exchanger with copper tubes and aluminum fins
        • Suitable for LPHW heating systems

        design trim

        • traffic white, similar to RAL 9016
        • Diffuser optimized for maximum comfort thanks to lateral air discharge and exploitation of the Coanda effect
        • IR receiver inconspicuously integrated in the design panel (with infrared remote control control control option)

        Fans

        • Stepless EC fans
        • Efficient and quiet
        • IP class IP 44, insulation class B
        • Integrated thermal contacts to prevent the motor from overheating

        Condensation pump and float switch

        • Easily accessible by removing the condensate tray
        • Integrated condensate pump removes the condensate up to a maximum delivery head of 600 mm
        • Control of the pump via a two-stage float switch
        • When the first stage is reached, the pump is switched on, the second stage activates an evaluable alarm contact

        Hydraulic connections

        • for PKW, PWW and condensate drainage
        • Valve drip tray drains any condensate into the condensate tray
        • Drip tray included with the unit
        • Optionally available with integrated valves for corresponding quantities

        Electrical junction box

        • KaControl
        • Infrared receiver electronics
        • Terminal points only, for on-site control

        Punched opening for optional fresh air connection

        • Model size 1-4 per spigot (max. 2) 80 m³/h
        • Model size 5 - 7 max. 120 m³/h

        Model size

        The units are available in several model sizes to allow the performance to be tailored to requirements. The model size is selected depending on the required thermal output, the air volume flow and the sound requirements of the room. Larger model sizes offer higher performance, but are associated with larger housing dimensions, which must be taken into account when planning the installation situation.

        Model sizePanel (A)Body (B)Height (C)
        1680 mm572 mm286 mm
        2680 mm572 mm286 mm
        3680 mm572 mm286 mm
        4680 mm572 mm286 mm
        5930 mm818 mm326 mm
        6930 mm818 mm326 mm
        7930 mm818 mm326 mm

        System

        2-pipe system

        With this design, the entire heat exchanger surface is available for temperature control, depending on the medium currently present in the pipe system (cold or hot water). Switch-over between heating and cooling takes place centrally via the building management system. This variant is particularly suitable for applications with seasonal switch-over and reduced installation effort.

        4-pipe system

        This version is suitable for sophisticated air conditioning concepts in which each room zone or unit can be switched over individually between heating and cooling. By routing the heating and cooling medium separately, the system offers maximum flexibility and comfort - ideal for buildings with changing usage requirements.

        Type of system
        2-pipe
        4-pipe

        panel

        The standard version "with panel" includes a visible cover made of ABS plastic.

        As an optical alternative, the unit can also be ordered "without panel". In this case, the ABS panel is omitted and a separate metal panel from the range of accessories can be used.

        panel
        with panel
        without panel

        Control option

        We offer various solutions for the control and regulation of our units, which can be used depending on the application and requirements:

        Electromechanical control

        This variant is ideal for simple applications. All integrated actuators are factory-wired to terminals and can be connected to our electromechanical accessories such as thermostats or external controllers.

        Infrared remote control

        Control of the various functions via an infrared remote control.

        KaControl MC1

        Our comprehensive comfort control offers extended control options for individual rooms or appliance groups. It can be operated either via a touch display or a web interface. Thanks to on-site 0-10 V control or common communication protocols such as Modbus RTU & TCP, BACnet and KNX, this solution is ideal for all BMS applications.

        Control option
        electromechanical
        IR remote control
        KaControl MC1

        Ceiling

        • Model sizes 1 to 4: Integration into a system ceiling or free-hanging installation, suspended ceiling frame optional
        • Model sizes 5 to 7: Integration into a system ceiling by averaging four ceiling grids or free-hanging installation, suspended ceiling frame optional
        • Further information on the suspended ceiling frame in the accessories

        Design ABS panel:

        • is part of the standard scope of delivery of KaCool D AF units
        • Optimized diffuser for comfortable air distribution
        • ISO Coarse air filter included
        • in RAL 9016 (standard)
        • Model sizes 1 to 4: 680 x 680 mm
        • Model sizes 5 to 7: 930 x 930 mm

        Alternative design metal cover optionally available:

        • Optimized diffuser for comfortable air distribution
        • ISO Coarse air filter included
        • in RAL 9016 (standard)
        • Model sizes 1 to 4: 623 x 623 mm
        • Model sizes 5 to 7: 923 x 923 mm

        Installation distances and heights

        • Mounting height max. 3.5 m
        • Wall distance min. 1.4 m
        • Device distance min. 4 m
        • If possible, stagger the units
        • Utilization of the Coanda effect through horizontal air distribution for a high throw
        • Slow and comfortable lowering of the conditioned air into the room

        Avoid the following:

        • Impairment of free air circulation due to e.g. lamps, furniture or shelves
        • Obstruction of air intake and air distribution
        • Electronic units below the unit
        • Inaccessibility for maintenance work

        Inspection hatches

        • When installing in closed ceilings, service hatches must be taken into account.
        • No additional service hatches need to be taken into account when installing in system ceilings.
        • Further information on the service hatches in the installation instructions.

        condensate drain

        When operating the unit below the dew point, note the following:

        • The maximum delivery height of the condensate pump is 600 m from the lower edge of the unit and must not be exceeded.
        • Condensate lines must be ventilated or vented. Provide lines with a permanent and continuous gradient (1%). Avoid inclines or so-called "water pockets". Use only fixed lines (no flexible hoses) for horizontal lines.
        • Connections and transitions (e.g. from hose to fixed line) must be tightly and mechanically secured, e.g. by the use of hose clamps.
        • If a siphon stop device is located at the transition point from the device to the on-site drain, it must be mounted at the highest point of the drainage profile.
        • Protect condensate-carrying lines against falling below the dew point, e.g. by means of vapour diffusion-tight insulation.

        External fresh air supply

        • Connection of centrally processed primary air to the device possible
        • permissible air temperature 14 - 15 °C
        • Primary air spigot available as an optional accessory
        • Connection diameter 80 mm
        • Models 1 – 4: max. two primary air connections, each 80 m³/h
        • Models 5 – 7: one primary air connection, max. 120 m³/h

        Supply to adjacent rooms:

        • Air conditioning of an adjacent room is possible via a secondary room connection.
        • a 150 mm diameter flange provided by the customer is required for connection to an air duct.
        • total pressure loss of up to 15 Pa must be taken into account.
        • up to 15% of the total air volume can be extracted.

        Hygiene compliance

        • Complies with the relevant hygiene guideline VDI 6022
        • Goal: Ensuring hygienic supply air that is harmless to health
        • Applies to common rooms such as workplaces, meeting rooms, break rooms, living rooms, sports facilities and sales rooms.
        • With factory-fitted ISO Coarse filter in the intake area.
        • Accessibility of all ventilated and water-bearing components for cleaning.

        Results per page

          Results per page

          Page 1 of 0

          Results per page

            Results per page

            Page 1 of 0

            KaCool D AF

            Comfortable feeling of well-being, thanks to AtmosFeel.

            • Heating
            • Cooling
            • Ventilation
            Product image
            Exploded view
            Hero image