Katherm HK P

Modular trench technology for heating and cooling with primary air supply

The optimized Katherm HK P in size 310/160 is based on a modular system design and is especially suitable for projects requiring both heating and cooling capacity as well as controlled ventilation. It features primary air connections with air nozzles or for air intake via the raised floor. The tangential fans operate quietly and energy-efficiently and ensure optimum air distribution.

  • Heating
  • Cooling
  • Ventilate
Im Boden an der Fensterfront des Hotelrestaurants installierte Katherm HK Unterflurkonvektoren.
Im Boden an der Fensterfront des Hotelrestaurants installierte Katherm HK Unterflurkonvektoren.

Primary air supply

Katherm HK P efficiently combines heating, cooling and fresh air supply via permanently integrated primary air connection nozzles in one system. Conditioned primary air is delivered into the room as required through air outlet openings on the window side. The channel design enables precise and individual regulation of the air volume by means of sliders.

Heating and cooling

The new trench technology unit Katherm HK P with an installation height of 160 mm, a width of 310 mm and a primary air connection achieves higher output through optimized components. It ensures efficient heating and cooling as well as controlled ventilation with minimal noise generation, regardless of the system temperature - even in low-temperature and heat pump applications. Its versatility allows use in various building types, especially those with high cooling demand due to internal heat loads or solar radiation through large glass facades.

Modular parametric design

The innovative modular concept of the Katherm HK P is divided into three core elements: connection module, power module and extension module. The parametric design of the power module, adjustable in 100-mm intervals, offers around 12,000 configuration options. This guarantees precise adaptation to the respective facade conditions with maximum output efficiency.

  1. Connection module
  2. Power module
  3. Extension module

252 variants

As a new variant in parametric design, the Katherm HK P is initially available in a fixed width and height. Depending on on-site requirements, various product-specific lengths are available in flexible increments to cover all performance requirements in both two-pipe and four-pipe systems.

Additional heights and widths (H/W) with supply air function via supply air modules or supply air ducts can be found here:

Connection module

The connection module contains the electrical connection and control box, the continuously variable EC fan motor, the water-side heat exchanger connection and the waste-water-side condensate connection with an optionally selectable condensate pump . Valve kits for 2- or 4-pipe systems are available on request. All electrical components are pre-installed in the central connection box. This module combines all connections to the electrical, heating and waste-water trades on one connection side, enabling efficient, time-saving installation.

Power module

With the power module in the Katherm HK P, we achieve higher heat exchanger output. A single powerful drive motor activates a series of tangential fans by means of an innovative coupling system. This cascading minimises performance losses and ensures uniform flow across the entire convector length. The use of fewer but more powerful motors reduces resource use, energy consumption and susceptibility to faults in projects. This makes the system an efficient and sustainable alternative to conventional multi-fan solutions.

Extension module

The newly designed Katherm HK P makes optimum use of the available floor space to achieve maximum output with low noise. In 4-pipe systems, the extension module (right channel section) serves as the additional valve connection for heating mode. In 2-pipe variants, the section is reduced to a minimum. Every millimeter is used efficiently and the channel is flexibly adapted to local conditions. This sophisticated design guarantees maximum space utilization of the trench unit.

Custom-made solutions

Our custom-made channel and grille solutions integrate seamlessly into any building structure. From miters and curves to angles, slopes and column surrounds – everything is possible. Various grille versions and frame designs are available to choose from.

Contact us for customized advice on the ideal solution for your project!

Contact

Optimum air outlet flow even in cooling mode

Katherm Hk glass facades

Optimum air outlet flow

  • Innovative airflow technology for minimizing short circuits and for homogeneous temperatures as well as maximum comfort
  • Thanks to the optimum channel design, air rises higher along the facade, promoting mixing and deeper room penetration
  • Flow-optimized roll-up and linear grilles enhance this effect
  • Efficient performance and pleasant indoor air quality

Comfort in cooling mode

  • Optimum indoor air quality even in cooling mode
  • Low outlet velocities and sophisticated air guidance enable draft-free cooling
  • Cool air rises along the facade, forming an expanding air flow and penetrating the room effectively
  • The method protects the facade and cools the interior space at the same time in an energy-saving manner

Heating and cooling connection

Our heat exchanger is equipped with an internal thread connection and an anti-torsion device, which also provides splash protection during venting. The valve range extends from adjustable on/off valve kits to pressure-independent valve kits for various flow rates, complete with corrugated pipes. All options can be preassembled at the factory, so that on site only one press connection on the copper end piece of the corrugated pipe is required .

Simple condensate management

Our system offers sophisticated condensate management with an integrated collection tray for reliable condensate drainage in cooling mode. Drainage takes place by natural gradient or by means of an optional pump, which can be installed on site or at the factory. The new pump design combines float and motor in one compact housing. A newly designed connection elbow for the tray is included, saving installation time and simplifying maintenance. The extremely quiet pump continuously adjusts its output. Preinstalled plug connections for power supply and fault signal also make maintenance easier.

Lowest noise through sound decoupling

Our system uses sound-decoupled tangential fans, which are mounted using a special coupling and ball stud mechanism to minimize operating noise. The fans can be removed without tools for maintenance – straightforward and time-saving. This ensures a pleasantly quiet room atmosphere together with effortless Maintenance.

Protection during installation and construction period

Protecting your systems is our highest priority during delivery and installation. That is why we protect every channel against construction waste with environmentally friendly paper. For the initial phase of interior finishing, an optional wooden cover ex works is available.

The grilles are delivered separately and securely packed by us to guarantee that they remain undamaged.

Control options

KaControl MC

With the integrated KaControl MC control, Katherm HK P offers bidirectional communication for up to 10 units within one group/room via CAN bus. With KaControl MC, the unit can be easily integrated into common building management systems such as Modbus RTU, Modbus TCP, BACnet/IP and KNX-TP

Electromechanical control

This variant is ideal for simple applications. All integrated actuators are factory-wired to a terminal and can be connected to our electromechanical accessories such as thermostats or external controllers.

Selection options

Adapt the product to your requirements these options are available for selection.

2‑pipe system

Heating or cooling (central switch-over possible)

4‑pipe system

Simultaneous heating and cooling in different usage zones

Design grilles

Wide range of versions in material and color. Can be used on both sides. Shortenings and extensions are also possible.

Product finder

With our free calculation program, you can find the product with the right performance data for your project in just a few steps. You can then download the official technical data sheet with your individual project values as a PDF.

Calculate product

VDI 6022 hygiene guideline

Our improved model in size 310/160 with primary air connection complies with the VDI 6022 hygiene standard. Condensate pump, connection and tray are installed in the trench unit. The tangential fan can be easily removed via plug connections, allowing the condensate tray to be pulled out for thorough cleaning. This sophisticated design guarantees hygienic and user-friendly operation.

Life cycle assessment data (EPDs)

We assess the environmental impact of our products across their entire life cycle („cradle to cradle“) and publish the results transparently in our Environmental Product Declarations (EPD). These EPDs can be easily integrated into leading building certification systems such as DGNB, BREEAM or LEED and are available in the download section.

ErP-compliant ventilation

Separate ventilation and temperature control with a hybrid ventilation concept: The combination of central ventilation via an AHU unit and decentralized air conditioning with pumped hot water and chilled water enables efficient heating and cooling.

Project solutions

Im Unterboden vor der Fensterfläche des Betriebsrestaurants installierte Sonderkonstruktion des Katherm HK Unterflurkonvektors mit Gehrungsecke.

Rheine

Apetito - company restaurant

Rheine

Apetito - company restaurant

  • New construction of a company restaurant
  • MDSCU (at a height of 5 m)
  • Optiline design grilles
  • Katherm HK (partly with and partly without supply air modules) 
#Heating and cooling ceiling systems
#Design grilles
#Trench technology
An einer Fensterfront im Boden installierte Katherm HK Unterflurkonvektoren.

Immenstadt

Albrecht Electrical Engineering

Immenstadt

Albrecht Electrical Engineering

  • Opening of a new location
  • 55 x KaCool D (old product series)
  • 3 x ProtecTor 
  • 4 x Katherm HK
  • Control technology KaControl
#Door air curtains
#Trench technology
#Control technology
An der Glasfassade eines Büroraumes installierte Katherm HK Unterflurkonvektoren.

Eislingen

Prinzing Electrical Engineering

Eislingen

Prinzing Electrical Engineering

  • New administrative center with attached boarding house
  • 144 x Katherm HK (366 meters)
  • Venkon
#Trench Technology
#Fan Coils
Ein montierter Unterflurkonvektor Katherm HK.

Lübeck-Travemünde

SlowDown

Lübeck-Travemünde

SlowDown

  • New conference hotel
  • 110 m² chilled ceiling
  • 112 x Venkon
  • diffusers DRS, SAL, DAL358
  • UniLine
  • Katherm HK
#Diffusers
#Door air curtains
#Trench technology
#Fan Coils
#Heating and chilled ceiling systems
Im Boden an der Fensterfront des Hotelrestaurants installierte Katherm HK Unterflurkonvektoren.

Berlin

Hotel RIU Plaza

Berlin

Hotel RIU Plaza

  • Revitalization of the hotel
  • 130 linear meters of Katherm HK
  • AHUs
#Trench technology
#AHUs
Im Unterboden vor der Fensterfläche des Betriebsrestaurants installierte Katherm HK Unterflurkonvektoren.

Riva del Garda TN, Italy

Hotel Lido Palace

Riva del Garda TN, Italy

Hotel Lido Palace

  • New hotel construction
  • Katherm HK (installation in the corridors, restaurants and in the spa - in the foyer incl. supply air function for combined heating and cooling with fresh air supply)
  • Design Grilles Optiline (Aluminium natural anodised)
  • Venkon
  • Tandem (in the suspended ceiling of the hotel entrance)
#trench technology
#Design grilles

Downloads

More Downloads

You can find more information about the downloads here.

Go to the download center

Frequently asked questions

Calculate now