• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Door Air Curtains
        • Tandem
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        Tandem EC

        Ambient and warm air stream for effective cold air screening.

        • Heating
        Product image
        Hero image
        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Downloads

        Radial fan

        • Patented generation of pre- and warm air curtains (Tandem technology) by a fan group for effective and energy-saving shielding of cold air to the outside
        • Direct-drive radial fan with forward-curved impellers in stepless EC design

        High-output heat exchanger

        • made of proven copper / aluminum combination

        Anti-twist device for heating connection

        • Prevents damage to the heat exchanger when screwing in the valves
        • Optional: Valves (accessories)

        Outlet air rectifier

        • Consisting of an aerodynamically shaped, adjustable lamella package
        • Air outlet rectifier in the discharge for minimum turbulence and uniformly directed air discharge, powder-coated RAL 9006
        • the emerging flat air stream tends to diverge less with improved depth effect, achieves significant reduction in air exchange
        • Adjustment range of up to 20° to adjust the direction of the air outlet

        Air inlet grille with filter (optional)

        • Can be opened with little effort
        • Uncomplicated filter change without the use of tools

        Execution

        The air discharge height describes the distance over which the air volume flow of an air curtain system ensures effective shielding between indoor and outdoor air.

        It is therefore a central criterion when selecting the right unit.

        Version
        Tandem 300
        Tandem 365

        discharge height

        By selecting the desired air discharge height, the unit design is determined by the difference in unit height.

        Discharge height
        2.7 - 3.2 m
        3.2 - 4.0 m

        Length

        The air curtains are available in different lengths.

        The appliance length must be selected so that the entire door width is covered.

        Length (A)Width (B)Height (C)
        1250 mm820 mm300 mm
        1250 mm985 mm365 mm
        2000 mm820 mm300 mm
        2000 mm985 mm365 mm
        2500 mm820 mm300 mm
        2750 mm985 mm365 mm
        3000 mm820 mm300 mm

        Control option

        We offer various solutions for the control and regulation of our units, which can be used depending on the application and requirements:

        Electromechanical control

        This variant is ideal for simple applications. All integrated actuators are factory-wired to terminals and can be connected to our electromechanical accessories such as thermostats or external controllers.

        KaControl MC1

        Our comprehensive comfort control offers extended control options for individual rooms or appliance groups. It can be operated either via a touch display or a web interface. Thanks to on-site 0-10 V control or common communication protocols such as Modbus RTU & TCP, BACnet and KNX, this solution is ideal for all BMS applications.

        Control option
        electromechanical
        Electromechanical with fault signal monitoring
        KaControl MC1

        Modular design

        • The device sizes are designed to fit common door opening dimensions.
        • Further installation lengths can be obtained by combining basic units of the same or different sizes, possibly with a corresponding connection set.
        • Installation lengths from 3 m can therefore be seamlessly extended using modular construction.

        Arrangement

        When placed above the door, the equipment must be installed so that the air outlet rectifier is placed as close as possible to the door opening. For larger distances:

        • Align the outlet rectifier
        • select the next longer device length
        • create lateral partitions similar to a corridor

        Operating limits

        Extremely unfavorable operating conditions, such as

        • strong negative pressure in the room, e.g. caused by mechanical ventilation without supply of outdoor air;
        • Extremely adverse weather conditions with high wind speeds in an unprotected location;
        • several open passages to the outside, especially if these are arranged opposite each other;

        can impair the effective shielding provided by door air curtains.

        Additional measures may be required here, e.g. for pressure equalization in the room.

        air outlet adjustment

        • To allow the air outlet to be designed according to individual preferences, the air outlet straightener has an adjustment range of 20°.
        • The air jet can be directed in a targeted and reliable manner to the outside or inside.

        Hygiene compliance

        • Complies with the relevant hygiene guideline VDI 6022
        • Goal: Ensuring hygienic supply air that is harmless to health
        • Applies to common rooms such as workplaces, meeting rooms, break rooms, living rooms, sports facilities and sales rooms.
        • With factory-fitted ISO Coarse filter in the intake area.
        • Accessibility of all ventilated and water-bearing components for cleaning.

        Results per page

          Results per page

          Page 1 of 0

          Results per page

            Results per page

            Page 1 of 0