Trench Technology
Katherm QK
Article no.:
14243113112700
List price
2,083.00 €
plus VAT
Overview
- All the installed components are centrally arranged on a terminal block
- Electric connection unit is positioned for ease of access
- Built-in 230 V/24 V power supply unit
- Control by Kampmann room thermostats or on-site controls
- Option to wire through to the next unit
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can be fed into rooms through the Katherm supply air module (Length 400 mm)
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 7.71E+01 | 5.59E+00 | 2.54E+00 | -3.02E+01 |
GWP - Biogenic | kg CO₂ eq | -1.67E+00 | 6.05E-01 | 1.02E-03 | -2.31E-02 |
GWP - Luluc | kg CO₂ eq | 9.87E-01 | 3.05E-02 | 1.32E-04 | -2.50E-01 |
GWP - Total | kg CO₂ eq | 7.64E+01 | 6.22E+00 | 2.54E+00 | -3.04E+01 |
ODP | kg CFC-11 eq | 6.58E-06 | 3.93E-07 | 5.25E-08 | -2.12E-06 |
AP | mol H+ eq | 7.25E-01 | 4.46E-02 | 1.06E-03 | -3.65E-01 |
EP - Freshwater | kg P eq | 6.25E-02 | 3.10E-03 | 3.43E-05 | -3.09E-02 |
EP - Marine | kg N eq | 1.47E-01 | 1.19E-02 | 3.62E-04 | -3.41E-02 |
EP - Terrestrial | mol N eq | 8.84E-01 | 6.27E-02 | 3.80E-03 | -3.89E-01 |
POCP | kg NMVOC | 2.62E-01 | 1.51E-02 | 9.11E-04 | -1.15E-01 |
ADPE | kg Sb eq | 8.25E-03 | 6.65E-04 | 8.38E-07 | -5.87E-03 |
ADPF | MJ | 1.06E+03 | 1.35E+02 | 2.65E+00 | -3.76E+02 |
WDP | m³ depriv. | 1.83E+01 | 9.38E-01 | 8.01E-02 | -5.31E+00 |
PM | disease inc. | 5.51E-06 | 1.72E-07 | 1.64E-08 | -2.18E-06 |
IR | kBq U-235 eq | 1.39E+01 | 4.50E+00 | 1.55E-02 | -3.49E+00 |
ETP - FW | CTUe | 4.40E+03 | 3.15E+02 | 1.10E+01 | -2.57E+03 |
HTP - C | CTUh | 3.46E-07 | 9.78E-09 | 4.06E-10 | -1.58E-07 |
HTP - NC | CTUh | 6.66E-06 | 4.16E-07 | 5.79E-09 | -3.97E-06 |
SQP | Pt | 5.64E+02 | 6.59E+01 | 3.76E+00 | -1.47E+02 |
PERE | MJ | 3.01E+02 | 2.57E+01 | 8.99E-02 | -7.61E+01 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 3.01E+02 | 2.57E+01 | 8.99E-02 | -7.61E+01 |
PENRE | MJ | 1.06E+03 | 1.35E+02 | 2.65E+00 | -3.76E+02 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 1.06E+03 | 1.35E+02 | 2.65E+00 | -3.76E+02 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 5.23E-01 | 5.95E-02 | 2.56E-03 | -1.88E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 3.63E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 1.10E+01 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 9.01E-01 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 7.58E+01 | 5.55E+00 | 2.54E+00 | -2.93E+01 |
Accessories
Control accessories electromechanical 230 V
Room thermostat
with speed setting, for continuously variable control, with thermal feedback, room temperature setting and speed pre-setting using a dial, 24 V DC, Surface-mounted, Protection class IP 30, Temperature setting range 5 - 30 °C, Colour white, Type 342924
Suitable for: EC units, electromechanical 230 V, 10 Katherm QK or Katherm QK nano Trench Technology, 3 PowerKon LT Fan Coils
Suitable for: EC units, electromechanical 230 V, 10 Katherm QK or Katherm QK nano Trench Technology, 3 PowerKon LT Fan Coils
Article no.:
194000342924
List price
118.00 €
plus VAT
Valve kits
Valve kit
includes 1 no. pre-settable valve body, straight, 1 no. thermoelectric actuator 24 V, 1 no. return shut-off valve, straight, 24 V actuator, Connection 1/2''
Article no.:
194000142110
List price
142.00 €
plus VAT
Valves and return shut-off valves
Valve body
straight, pre-settable, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), DN 15
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), DN 15
Article no.:
194000346909
List price
39.00 €
plus VAT
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
List price
7.00 €
plus VAT
Return shut-off valve
Straight, Connection 1/2''
Article no.:
194000145952
List price
21.00 €
plus VAT
Valve actuators
Thermoelectric actuator
24 V AC/DC
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Article no.:
194000146906
List price
84.00 €
plus VAT
Mitred corners
Mitred corner
Roll-up grille Aluminium, natural anodised, 90 degrees, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Article no.:
194000142522
List price
722.00 €
plus VAT
Mitred corner
Roll-up grille Aluminium, natural anodised, other angles, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Article no.:
194000142622
List price
840.00 €
plus VAT
Mitred corner
Linear grille Aluminium, natural anodised, 90 degrees, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Article no.:
194000142722
List price
492.00 €
plus VAT
Mitred corner
Linear grille Aluminium, natural anodised, other angles, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Article no.:
194000142822
List price
576.00 €
plus VAT
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Width 215 mm
price per m
Suitable for: Width 215 mm
Article no.:
194000100922
List price
18.00 €
plus VAT
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
EU Declaration of Conformity Katherm trench heating
PDF
(457 kB)
Digital EPD database Katherm QK
EPD for Katherm QK
PDF
(2.7 MB)
Cross-product information
Products
PDF
(17.9 MB)
Convection and Radiation
PDF
(1.2 MB)
Trench Technology – For a comfortable room climate
PDF
(6.7 MB)
Kampmann hotel references
PDF
(6.2 MB)
Information sheet DIN EN 16430 for trench heaters
PDF
(683 kB)
Overview Katherm supply air versions
PDF
(4 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm QK, QK nano trench heating
PDF
(12.7 MB)
Manuals
Katherm QK, brief instructions
PDF
(4 MB)
Katherm QK trench heating
PDF
(5.1 MB)
Katherm QK - Wiring diagrams, control KaControl
PDF
(1.8 MB)
Katherm QK - Wiring Diagrams, electromechanical control
PDF
(1.2 MB)
CAD-Drawings
Katherm QK 215, PDF top view
PDF
(1.2 MB)
Katherm QK 215, PDF cross-sections
PDF
(90 kB)
Katherm QK 215, PDF front views
PDF
(130 kB)
Katherm QK 215, DWG top view
DWG
(4 MB)
Katherm QK 215, DWG cross-sections
DWG
(394 kB)
Katherm QK 215, DWG front views
DWG
(361 kB)
Installation plans
Katherm QK, electromechanical control
PDF
(1.4 MB)