Trench Technology
Katherm HK
Article no.:
14332631133500
List price
3,481.00 €
plus VAT
Overview
- All the installed components are centrally arranged on a terminal block
- Electric connection unit is positioned for ease of access
- Built-in 230 V/24 V power supply unit
- Control by Kampmann room thermostats or on-site controls
- Option to wire through to the next unit
Katherm HK units with supply air function are perfectly suited to supply primary air (fresh air) into a space, seamlessly combining heating, cooling and a supply of fresh air. There are two versions available: primary air intake via supply air modules or through supply air trenches. In both versions, the primary air volume flow exits the trench at a minimal and low-turbulence air discharge speed. The volume of air supplied can be adjusted as required by means of air sliders.
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- In a 2-pipe version for additional electric heating
- With integral, continuously variably controllable electric heating coil
- With built-in safety chain consisting of 2 safety temperature switches
- Sustainable 4-pipe system solution at the cost of a 2-pipe system
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 1.48E+02 | 3.63E+02 | 5.19E+00 | -8.82E+01 |
GWP - Biogenic | kg CO₂ eq | 4.26E-01 | 2.24E-01 | 4.75E-04 | -2.36E-01 |
GWP - Luluc | kg CO₂ eq | 1.32E+00 | 4.58E-01 | 2.50E-04 | -9.78E-01 |
GWP - Total | kg CO₂ eq | 1.50E+02 | 3.63E+02 | 5.19E+00 | -8.93E+01 |
ODP | kg CFC-11 eq | 3.38E-06 | 1.84E-05 | 2.77E-08 | -2.34E-06 |
AP | mol H+ eq | 1.78E+00 | 9.93E-01 | 2.07E-03 | -1.23E+00 |
EP - Freshwater | kg P eq | 1.53E-01 | 4.17E-02 | 6.40E-05 | -1.03E-01 |
EP - Marine | kg N eq | 1.82E-01 | 2.60E-01 | 7.54E-04 | -1.09E-01 |
EP - Terrestrial | mol N eq | 2.03E+00 | 2.95E+00 | 7.88E-03 | -1.24E+00 |
POCP | kg NMVOC | 7.72E-01 | 8.60E-01 | 2.77E-03 | -4.93E-01 |
ADPE | kg Sb eq | 1.52E-02 | 1.78E-03 | 1.17E-06 | -1.11E-02 |
ADPF | MJ | 1.98E+03 | 9.41E+03 | 6.18E+00 | -1.16E+03 |
WDP | m³ depriv. | 3.52E+01 | 1.61E+01 | 1.62E-01 | -1.72E+01 |
PM | disease inc. | 1.22E-05 | 6.06E-06 | 4.19E-08 | -7.29E-06 |
IR | kBq U-235 eq | 1.98E+01 | 3.23E+02 | 1.24E-02 | -1.24E+01 |
ETP - FW | CTUe | 1.90E+03 | 7.04E+02 | 1.33E+01 | -1.28E+03 |
HTP - C | CTUh | 7.30E-07 | 1.14E-07 | 5.64E-10 | -4.43E-07 |
HTP - NC | CTUh | 1.74E-05 | 3.11E-06 | 6.78E-09 | -1.25E-05 |
SQP | Pt | 1.34E+03 | 4.08E+03 | 8.53E+00 | -3.78E+02 |
PERE | MJ | 5.82E+02 | 2.10E+03 | 1.56E-01 | -2.92E+02 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 5.82E+02 | 2.10E+03 | 1.56E-01 | -2.92E+02 |
PENRE | MJ | 1.98E+03 | 9.41E+03 | 6.18E+00 | -1.16E+03 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 1.98E+03 | 9.41E+03 | 6.18E+00 | -1.16E+03 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 1.24E+00 | 2.40E+00 | 7.33E-03 | -6.67E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 9.33E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 2.79E+01 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 2.04E+00 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 1.50E+02 | 3.63E+02 | 5.19E+00 | -8.95E+01 |
Accessories
Control accessories electromechanical 230 V
Room temperature controller
Heating/Cooling, with setpoint display by means of arrow indicators, for heating or cooling systems, 24 V AC/DC, 0 - 10 V, 50 Hz, Surface-mounted, Protection class III, Protection class IP 30, Temperature setting range 13 - 29 °C, Colour similar to RAL 9010 pure white, Type 146828
optional connectible, remote sensor art. no. 196000148921
Suitable for: 2/4-pipe version, 5 Katherm QE or Katherm HK 320 E Trench Technology
optional connectible, remote sensor art. no. 196000148921
Suitable for: 2/4-pipe version, 5 Katherm QE or Katherm HK 320 E Trench Technology
Article no.:
194000146928
List price
372.00 €
plus VAT
Control accessories electromechanical 24 V
Clock thermostat
Heating/Cooling, 2- and 4-pipe, continuously variable, with LCD operating menu and integrated timer program, heating/cooling changeover by means of external potential-free contact (low voltage), 24 V Actuator, Open/Closed, 1 W, flush-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30456
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Article no.:
196000030456
List price
410.00 €
plus VAT
Valve kits
Valve kit
Heating/Cooling, 2-pipe, includes pre-adjustable valve, angled return shut-off valve, with an axial valve, pre-adjustable, and an angled return shut-off valve, 24 V actuator, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar, supplied separately
Suitable for: DN 15
Suitable for: DN 15
Article no.:
194000143211
List price
151.00 €
plus VAT
Valve kit
Heating/Cooling, 2-pipe, 1 pre-adjustable valve, actuator, angled return shut-off valve, 24 V actuator, with an axial valve, pre-adjustable, and an angled return shut-off valve, Connection 1/2'', kvs value 2.65 m³/h, Max. operating pressure 16 bar, supplied separately
Suitable for: for higher flow from 250 l/h, DN 15
Suitable for: for higher flow from 250 l/h, DN 15
Article no.:
194000143241
List price
155.00 €
plus VAT
Valves and return shut-off valves
Valve body
Axial, pre-settable, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), DN 15
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), DN 15
Article no.:
194000346911
List price
39.00 €
plus VAT
Valve body
Axial, pre-settable, Connection 1/2'', kvs value 2.65 m³/h, Max. operating pressure 16 bar
Suitable for: for higher flow from 250 l/h, DN 15
Suitable for: for higher flow from 250 l/h, DN 15
Article no.:
194000346914
List price
51.00 €
plus VAT
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
List price
7.00 €
plus VAT
Pre-setting set
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Article no.:
194000346916
List price
38.00 €
plus VAT
Return shut-off valve
Straight, Connection 1/2''
Article no.:
194000145952
List price
21.00 €
plus VAT
Return shut-off valve
angled, Connection 1/2''
Article no.:
194000145953
List price
21.00 €
plus VAT
Return shut-off valve
Straight, Connection 1/2''
Suitable for: for higher flow from 250 l/h
Suitable for: for higher flow from 250 l/h
Article no.:
194000145954
List price
34.00 €
plus VAT
Return shut-off valve
angled, Connection 1/2''
Suitable for: for higher flow from 250 l/h
Suitable for: for higher flow from 250 l/h
Article no.:
194000145955
List price
31.00 €
plus VAT
Valve actuators
Thermoelectric actuator
24 V AC/DC
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Article no.:
194000146906
List price
84.00 €
plus VAT
Filter
Filter for air inlet
Replacement filter without frame, ISO Coarse 30% filter (G2)
Suitable for: Length 2000 mm
Suitable for: Length 2000 mm
Article no.:
143014313035
List price
34.00 €
plus VAT
Condensate tray/pump
Connection kit for condensation pump
230 V 50 Hz, 20 W, supplied separately, Type 143813
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Article no.:
194000143813
List price
301.00 €
plus VAT
Connection kit for condensation pump
230 V 50 Hz, 20 W, factory-fitted, Type 143814
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Article no.:
194000143814
List price
445.00 €
plus VAT
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Width 320 mm
price per m
Suitable for: Width 320 mm
Article no.:
194000100320
List price
22.00 €
plus VAT
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
EU Declaration of Conformity Katherm trench heating
PDF
(457 kB)
Digital EPD database Katherm HK E
Digital EPD database Katherm HK
EPD Katherm HK E
PDF
(1.6 MB)
EPD Katherm HK
PDF
(2.5 MB)
Cross-product information
Products
PDF
(17.9 MB)
Convection and Radiation
PDF
(1.2 MB)
Trench Technology – For a comfortable room climate
PDF
(6.7 MB)
Kampmann hotel references
PDF
(6.2 MB)
Information sheet DIN EN 16430 for trench heaters
PDF
(683 kB)
Overview Katherm supply air versions
PDF
(4 MB)
Manuals
Katherm HK trench heating
PDF
(7.7 MB)
Katherm HK, brief instructions
PDF
(3.8 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm HK trench heating
PDF
(17.3 MB)
CAD-Drawings
Katherm HKE, Kanalbreite 320mm, Kanalhöhe 130 mm, 2-Leiter + E, Abmessungen [Inch]
PDF
(395 kB)
Katherm HKE, Kanalbreite 320mm, Kanalhöhe 130 mm, 2-Leiter + E, Abmessungen [mm]
PDF
(402 kB)
Katherm HKE, Kanalbreite 320mm, Kanalhöhe 130 mm, 2-Leiter + E, Abmessungen [mm]
DWG
(863 kB)
Katherm HKE, Kanalbreite 320mm, Kanalhöhe 130 mm, 2-Leiter + E, Abmessungen [Inch]
DWG
(869 kB)