Katherm HK
Overview
- KaControl control system for operation via a separate room control unit, external control via a 0-10 V signal or building automation systems, such as KNX, modbus, BACnet (additional plug-in card accessory required)
- Room control of up to six units or up to 30 units with CANbus cards that are additionally required
- Demand-led automatic fan or optional manual fan control
- Connection options, including external room sensor, window contact etc.
- Individually parametrisable for optimum adaptation to the situation on site
The KaControl control option provides the option of omitting the valve control data point when externally controlled by an on-site 0-10 V signal. The fan valve and speed control logic comes from the KaControl. Note the deviation of the signal points from the design program with 0-10 V control by others.
Design program data: 2 V 4 V 6 V 8 V 10 V
External 0-10 V on the KaControl: 4.3 V 5.5 V 6.8 V 7.8 V 10 V
Katherm HK units with supply air function are perfectly suited to supply primary air (fresh air) into a space, seamlessly combining heating, cooling and a supply of fresh air. There are two versions available: primary air intake via supply air modules or through supply air trenches. In both versions, the primary air volume flow exits the trench at a minimal and low-turbulence air discharge speed. The volume of air supplied can be adjusted as required by means of air sliders.
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- In a 2-pipe version for additional electric heating
- With integral, continuously variably controllable electric heating coil
- With built-in safety chain consisting of 2 safety temperature switches
- Sustainable 4-pipe system solution at the cost of a 2-pipe system
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
Calculate performance data
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 2.41E+02 | 1.61E+01 | 9.26E+00 | -1.05E+02 |
GWP - Biogenic | kg CO₂ eq | -7.02E+00 | 1.89E+00 | 3.64E-03 | -5.13E-02 |
GWP - Luluc | kg CO₂ eq | 2.41E+00 | 6.23E-02 | 4.54E-04 | -7.65E-01 |
GWP - Total | kg CO₂ eq | 2.37E+02 | 1.81E+01 | 9.26E+00 | -1.07E+02 |
ODP | kg CFC-11 eq | 1.97E-05 | 1.09E-06 | 1.82E-07 | -7.11E-06 |
AP | mol H+ eq | 2.65E+00 | 1.31E-01 | 3.77E-03 | -1.55E+00 |
EP - Freshwater | kg P eq | 2.31E-01 | 1.11E-02 | 1.19E-04 | -1.28E-01 |
EP - Marine | kg N eq | 2.78E-01 | 1.53E-02 | 1.28E-03 | -1.32E-01 |
EP - Terrestrial | mol N eq | 3.01E+00 | 1.81E-01 | 1.47E-02 | -1.53E+00 |
POCP | kg NMVOC | 8.78E-01 | 4.52E-02 | 3.22E-03 | -4.43E-01 |
ADPE | kg Sb eq | 3.68E-02 | 3.71E-03 | 2.87E-06 | -2.93E-02 |
ADPF | MJ | 3.26E+03 | 3.99E+02 | 9.43E+00 | -1.30E+03 |
WDP | m³ depriv. | 6.28E+01 | 2.57E+00 | 2.89E-01 | -2.29E+01 |
PM | disease inc. | 1.77E-05 | 4.71E-07 | 5.74E-08 | -8.02E-06 |
IR | kBq U-235 eq | 3.65E+01 | 1.32E+01 | 5.49E-02 | -1.12E+01 |
ETP - FW | CTUe | 1.69E+04 | 8.79E+02 | 3.86E+01 | -1.13E+04 |
HTP - C | CTUh | 1.18E-06 | 3.07E-08 | 1.22E-09 | -6.01E-07 |
HTP - NC | CTUh | 2.68E-05 | 1.27E-06 | 1.96E-08 | -1.77E-05 |
SQP | Pt | 1.88E+03 | 1.77E+02 | 1.34E+01 | -6.19E+02 |
PERE | MJ | 8.96E+02 | 7.40E+01 | 3.08E-01 | -2.49E+02 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 8.96E+02 | 7.40E+01 | 3.08E-01 | -2.49E+02 |
PENRE | MJ | 3.26E+03 | 3.99E+02 | 9.43E+00 | -1.30E+03 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 3.26E+03 | 3.99E+02 | 9.43E+00 | -1.30E+03 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 1.54E+00 | 1.61E-01 | 1.19E-02 | -7.22E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 1.29E+01 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 3.92E+01 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 3.09E+00 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 2.37E+02 | 1.60E+01 | 9.26E+00 | -1.03E+02 |
Accessories
KaController
Suitable for: all units with control option KaControl -C1
KaController
Suitable for: all units with control option KaControl -C1
KaController
Suitable for: all units with control option KaControl -C1
Room temperature sensor
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Serial KNX card
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Serial CANbus card
Suitable for: all units with control option KaControl -C1
Serial Modbus card
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Valve kit
Suitable for: DN 15
Valve kit
Suitable for: for higher flow from 250 l/h, DN 15
Valve body
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), DN 15
Valve body
Suitable for: for higher flow from 250 l/h, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Pre-setting set
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Return shut-off valve
Return shut-off valve
Return shut-off valve
Suitable for: for higher flow from 250 l/h
Return shut-off valve
Suitable for: for higher flow from 250 l/h
Thermoelectric actuator
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Filter for air inlet
Suitable for: Length 3000 mm
Connection kit for condensation pump
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Connection kit for condensation pump
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Installation cover
price per m