Katherm HK
Overview
- KaControl control system for operation via a separate room control unit, external control via a 0-10 V signal or building automation systems, such as KNX, modbus, BACnet (additional plug-in card accessory required)
- Room control of up to six units or up to 30 units with CANbus cards that are additionally required
- Demand-led automatic fan or optional manual fan control
- Connection options, including external room sensor, window contact etc.
- Individually parametrisable for optimum adaptation to the situation on site
The KaControl control option provides the option of omitting the valve control data point when externally controlled by an on-site 0-10 V signal. The fan valve and speed control logic comes from the KaControl. Note the deviation of the signal points from the design program with 0-10 V control by others.
Design program data: 2 V 4 V 6 V 8 V 10 V
External 0-10 V on the KaControl: 4.3 V 5.5 V 6.8 V 7.8 V 10 V
Katherm HK units with supply air function are perfectly suited to supply primary air (fresh air) into a space, seamlessly combining heating, cooling and a supply of fresh air. There are two versions available: primary air intake via supply air modules or through supply air trenches. In both versions, the primary air volume flow exits the trench at a minimal and low-turbulence air discharge speed. The volume of air supplied can be adjusted as required by means of air sliders.
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- In a 2-pipe version for additional electric heating
- With integral, continuously variably controllable electric heating coil
- With built-in safety chain consisting of 2 safety temperature switches
- Sustainable 4-pipe system solution at the cost of a 2-pipe system
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
Calculate performance data
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 2.00E+02 | 1.33E+01 | 7.65E+00 | -8.72E+01 |
GWP - Biogenic | kg CO₂ eq | -5.80E+00 | 1.56E+00 | 3.01E-03 | -4.24E-02 |
GWP - Luluc | kg CO₂ eq | 1.99E+00 | 5.15E-02 | 3.75E-04 | -6.33E-01 |
GWP - Total | kg CO₂ eq | 1.96E+02 | 1.49E+01 | 7.65E+00 | -8.81E+01 |
ODP | kg CFC-11 eq | 1.63E-05 | 9.00E-07 | 1.50E-07 | -5.87E-06 |
AP | mol H+ eq | 2.19E+00 | 1.08E-01 | 3.11E-03 | -1.28E+00 |
EP - Freshwater | kg P eq | 1.91E-01 | 9.18E-03 | 9.86E-05 | -1.06E-01 |
EP - Marine | kg N eq | 2.29E-01 | 1.26E-02 | 1.05E-03 | -1.09E-01 |
EP - Terrestrial | mol N eq | 2.49E+00 | 1.49E-01 | 1.21E-02 | -1.27E+00 |
POCP | kg NMVOC | 7.26E-01 | 3.74E-02 | 2.66E-03 | -3.66E-01 |
ADPE | kg Sb eq | 3.04E-02 | 3.06E-03 | 2.37E-06 | -2.42E-02 |
ADPF | MJ | 2.69E+03 | 3.30E+02 | 7.79E+00 | -1.07E+03 |
WDP | m³ depriv. | 5.19E+01 | 2.13E+00 | 2.39E-01 | -1.89E+01 |
PM | disease inc. | 1.46E-05 | 3.89E-07 | 4.74E-08 | -6.63E-06 |
IR | kBq U-235 eq | 3.02E+01 | 1.09E+01 | 4.54E-02 | -9.29E+00 |
ETP - FW | CTUe | 1.40E+04 | 7.26E+02 | 3.19E+01 | -9.34E+03 |
HTP - C | CTUh | 9.77E-07 | 2.54E-08 | 1.01E-09 | -4.96E-07 |
HTP - NC | CTUh | 2.21E-05 | 1.05E-06 | 1.62E-08 | -1.46E-05 |
SQP | Pt | 1.55E+03 | 1.46E+02 | 1.11E+01 | -5.12E+02 |
PERE | MJ | 7.41E+02 | 6.12E+01 | 2.54E-01 | -2.06E+02 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 7.41E+02 | 6.12E+01 | 2.54E-01 | -2.06E+02 |
PENRE | MJ | 2.69E+03 | 3.30E+02 | 7.79E+00 | -1.07E+03 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 2.69E+03 | 3.30E+02 | 7.79E+00 | -1.07E+03 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 1.28E+00 | 1.33E-01 | 9.81E-03 | -5.96E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 1.07E+01 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 3.24E+01 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 2.55E+00 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 1.96E+02 | 1.32E+01 | 7.65E+00 | -8.48E+01 |
Accessories
KaController
Suitable for: all units with control option KaControl -C1
KaController
Suitable for: all units with control option KaControl -C1
KaController
Suitable for: all units with control option KaControl -C1
Room temperature sensor
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Serial KNX card
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Serial CANbus card
Suitable for: all units with control option KaControl -C1
Serial Modbus card
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Valve kit
Suitable for: DN 15
Valve kit
Suitable for: for higher flow from 250 l/h, DN 15
Valve body
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), DN 15
Valve body
Suitable for: for higher flow from 250 l/h, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Pre-setting set
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Return shut-off valve
Return shut-off valve
Return shut-off valve
Suitable for: for higher flow from 250 l/h
Return shut-off valve
Suitable for: for higher flow from 250 l/h
Thermoelectric actuator
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Filter for air inlet
Suitable for: Length 2500 mm
Connection kit for condensation pump
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Connection kit for condensation pump
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Installation cover
price per m